Comparison of Inversion ("flipping") Rates Among Different Port Designs: A Single-Center Experience

Vahid Etezadi1,2, Scott O Trerotola3

  • 1Division of Interventional Radiology, Department of Radiology, University of Pennsylvania Medical Center, 1 Silverstein, 3400 Spruce Street, Philadelphia, PA, 19104, USA.

Abstract

Related Concept Videos

Transmission Line Design Considerations01:23

Transmission Line Design Considerations

Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
684
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
551
Equivalent Resistance01:16

Equivalent Resistance

In circuit analysis, situations often arise where resistors are neither in series nor parallel configurations. To tackle such scenarios, three-terminal equivalent networks like the wye (Y) (Figure 1 (a)) or tee (T) and delta (Δ) (Figure 1 (b)) or pi (π) networks come into play. These networks offer versatile solutions and are frequently encountered in various applications, including three-phase electrical systems, electrical filters, and matching networks.
1.1K
Transformers with Off-Nominal Turns Ratios01:25

Transformers with Off-Nominal Turns Ratios

In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
635
Reynolds Transport Theorem01:24

Reynolds Transport Theorem

The Reynolds transport theorem provides a framework to relate the time rate of change of an extensive property within a system to that in a control volume, which is crucial for analyzing fluid dynamics. Extensive properties, such as mass, velocity, acceleration, temperature, and momentum, can be expressed in terms of the mass of a fluid portion. These properties are called extensive because they depend on the system's size, while intensive properties are their corresponding values per unit...
2.0K
Structure of Porins01:21

Structure of Porins

Mitochondria, chloroplasts, and gram-negative bacteria have transmembrane, beta-barrel proteins called porins to mediate the free diffusion of ions and metabolites across the membrane. Mitochondrial porin precursors contain conserved amino acid sequences called beta signals at their C-terminal. Beta signals have a  motif of PoXGXXHyXHy (Po-Polar, X-Any amino acid, G-Glycine, Hy-LargeHydrophobic), which are crucial for precursor recognition to initiate precursor assembly. Beta-barrel...
4.1K