Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mitral Stenosis III: Medical Management01:26

Mitral Stenosis III: Medical Management

399
Mitral stenosis, a condition marked by the narrowing of the mitral valve, necessitates an integrated approach for effective management. This approach includes preventative measures, medical therapy, and surgical interventions to reduce symptoms and prevent complications.PreventionPrevention of mitral stenosis primarily focuses on reducing the incidence of bacterial infections, particularly streptococcal infections, which can lead to rheumatic fever and subsequent valvular damage. Timely...
399
Heart Valves01:16

Heart Valves

13.1K
The human heart is a complex organ with an intricate system of valves that regulate blood flow. There are two main types of valves: atrioventricular (AV) valves and semilunar valves.
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
13.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Health executive and IPA in psychiatry: essential co-leadership and complementarity].

Soins. Psychiatrie·2025
Same author

Fissurating aneurysm of the right coronary artery repaired with interposition of a Gore-Tex graft.

Multimedia manual of cardiothoracic surgery : MMCTS·2025
Same author

Minimally Invasive Mitral Valve Repair With New-Generation Annuloplasty Ring: Results From the International Prospective MANTRA Study.

Innovations (Philadelphia, Pa.)·2025
Same author

Safety and efficacy of the automated suture system in valvular heart surgery: a multicenter, prospective registry.

The Journal of cardiovascular surgery·2025
Same author

Mitral valve repair with the semi-rigid Memo 4D annuloplasty ring: early clinical and echocardiographic outcomes from the MANTRA study.

Interdisciplinary cardiovascular and thoracic surgery·2024
Same author

Resection of a cardiac tumour with reconstruction of the atria and the superior vena cava.

Multimedia manual of cardiothoracic surgery : MMCTS·2023

Related Experiment Video

Updated: Mar 9, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
11:12

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

Published on: October 17, 2013

14.3K

A Standardized Loop Technique for Mitral Valve Repair.

Ilir Hysi1, Olivier Rebet1, Laurence Gautier1

  • 1Department of Cardiac Surgery, Lens Hospital and Ramsay Bois Bernard Private Hospital, Lens, France.

The Annals of Thoracic Surgery
|December 24, 2016
PubMed
Summary

A new standardized loop technique improves mitral valve repair by using fixed 15- and 25-mm loops for prolapses. This method offers reliable initial results in both sternotomy and minimally invasive surgeries.

More Related Videos

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

14.8K
Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
06:56

Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies

Published on: August 25, 2023

1.7K

Related Experiment Videos

Last Updated: Mar 9, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
11:12

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

Published on: October 17, 2013

14.3K
Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

14.8K
Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
06:56

Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies

Published on: August 25, 2023

1.7K

Area of Science:

  • Cardiovascular Surgery
  • Cardiac Valve Repair
  • Medical Device Technology

Background:

  • The loop technique is a common method for mitral valve repair.
  • Accurately determining loop length for mitral valve repair can be difficult.
  • Mitral valve prolapse requires effective surgical solutions.

Purpose of the Study:

  • To introduce a standardized loop implantation technique for mitral valve repair.
  • To address the challenge of estimating correct loop lengths in mitral valve repair.
  • To evaluate the initial efficacy of standardized loops in mitral valve prolapse repair.

Main Methods:

  • Describing a standardized surgical technique using 15-mm and 25-mm loops.
  • Implanting standardized loops for both posterior and anterior mitral prolapses.
  • Determining the number and placement of loops based on surgical valve analysis.

Main Results:

  • The technique demonstrated reliable initial results in eight patients.
  • Successful application in both sternotomy and minimally invasive mitral valve repair procedures.
  • Standardized loops provided consistent outcomes in the initial patient cohort.

Conclusions:

  • The described standardized loop technique is a promising approach for mitral valve repair.
  • This method simplifies loop implantation and yields reliable early outcomes.
  • Further long-term evaluation is necessary to confirm the durability of this technique.