Related Experiment Video
Updated: Mar 9, 2026

Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Physical compatibility of isavuconazonium sulfate with select i.v. drugs during simulated Y-site administration
Wonhee So1, Liz Kim2, Abrar K Thabit3
1Center for Anti-Infective Research and Development, Hartford Hospital, Hartford, CT.
Purpose:
The physical compatibility of isavuconazonium sulfate with 95 i.v. drugs during simulated Y-site administration was studied.
Methods:
Isavuconazonium sulfate for injection and all other drugs were reconstituted according to the manufacturer's recommendation and further diluted with 0.9% sodium chloride injection or 5% dextrose injection to a final concentration (1.5 mg/mL for isavuconazonium sulfate and standard concentrations used clinically for other drugs). A Y site was simulated in glass culture tubes by mixing 5 mL of the tested drug and isavuconazonium sulfate solutions in each diluent. Incompatibility was defined as changes in visual characteristics or increases in turbidity by greater than 0.5 nephelometric turbidity units over the 120-minute experiment.
Results:
Of the 95 drugs tested, isavuconazonium sulfate was physically compatible with 66 drugs in 0.9% sodium chloride injection and 60 drugs in 5% dextrose injection. Incompatibility was observed with albumin, amphotericin B deoxycholate, amphotericin B lipid complex, amphotericin B liposome, ampicillin-sulbactam, cefazolin, cefepime, ceftaroline fosamil, ceftazidime, ceftriaxone, cefuroxime, colistimethate sodium, cyclosporine, ertapenem, esomeprazole, filgrastim, fosphenytoin, furosemide, heparin, meropenem, methylprednisolone, micafungin, phenytoin, potassium phosphate, propofol, sodium bicarbonate, sodium phosphate, and tedizolid. Azithromycin, bumetanide, penicillin G potassium, and piperacillin-tazobactam were incompatible with isavuconazonium sulfate in 5% dextrose injection only.
Conclusion:
Of the 95 drugs tested, isavuconazonium sulfate 1.5 mg/mL was physically compatible with 66 drugs in 0.9% sodium chloride injection and 60 drugs in 5% dextrose injection. Incompatibility was observed with 18 antimicrobials, including most cephalosporins tested, and 14 other i.v. drugs in at least 1 of the 2 tested diluents.
More Related Videos
06:34Validation of Therapeutic Agent Conjugation to Polyvinyl Alcohol-Coated Medical Devices
Published on: November 29, 2024
08:44Continuous IV Infusion is the Choice Treatment Route for Arginine-vasopressin Receptor Blocker Conivaptan in Mice to Study Stroke-evoked Brain Edema
Published on: September 1, 2016
Related Concept Videos
Drug Product Performance: In Vitro–In Vivo Correlation
Dosage Interval and Administration Route: Determination Methods
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
IV Infusion to Oral Dosing: Conversion Methods
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...