Related Experiment Video
Updated: Mar 9, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Impact of LVAD Implantation Site on Ventricular Blood Stagnation
Anthony R Prisco1, Alberto Aliseda, Jennifer A Beckman
1From the *Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin; †Department of Medicine, University of Minnesota, Minneapolis, Minnesota; ‡Department of Mechanical Engineering, University of Washington, Seattle, Washington; §Department of Medicine, Division of Cardiology, University of Washington, Seattle, Washington; ¶Department of Surgery, Division of Cardiothoracic Surgery, University of Washington, Seattle, Washington; and ‖Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin.
Abstract:
Treatment of end-stage heart failure includes cardiac transplantation or ventricular assist device (VAD) therapy. Although increasingly prevalent, current VAD therapy has inherent complications, including thrombosis. Studies have demonstrated that VAD implantation alters intracardiac blood flow, creating areas of stagnation that predispose to thrombus formation. Two potential surgical configurations exist for VAD implantation: through the apical or diaphragmatic surfaces of the heart. We hypothesized that diaphragmatic implantation causes more stagnation than apical implantation. We also hypothesized that intermittent aortic valve (AV) opening reduces stagnation of blood inside the left ventricle (LV) when compared with a closed AV. To test these hypotheses, a human LV geometry was recreated in silico and a VAD inflow cannula was virtually implanted in each configuration. A computational indicator-dilution study was conducted where "virtually dyed blood" was washed out of the LV by injecting blood with no dye. Simulations demonstrated a substantial reduction in stagnation with intermittent AV opening. In addition, virtual dye was cleared slightly faster in the apical configuration. Simulations from our study demonstrate the clinical importance of VAD management to allow intermittent opening of the AV to prevent subvalvular stagnation, and also suggests that apical configuration might be more hemodynamically favorable.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021