Derivation of respiration rate from ambulatory ECG and PPG using Ensemble Empirical Mode Decomposition: Comparison
1Department of Electrical and Computer Engineering, University of Cyprus, University House "Anastasios G. Leventis", Panepistimiou Avenue, 2109 Aglanzia, P.O.Box. 20537, 1678 Nicosia, Cyprus; Kios Centre for Intelligent Systems and Networks, University of Cyprus, P.O.Box 20537, 1678 Nicosia, Cyprus; Oxygen Research Ltd, Vassileos Constantinou 8, Limassol 3075, Cyprus.
Abstract:
A new method for extracting the respiratory rate from ECG and PPG obtained via wearable sensors is presented. The proposed technique employs Ensemble Empirical Mode Decomposition in order to identify the respiration "mode" from the noise-corrupted Heart Rate Variability/Pulse Rate Variability and Amplitude Modulation signals extracted from ECG and PPG signals. The technique was validated with respect to a Respiratory Impedance Pneumography (RIP) signal using the mean absolute and the average relative errors for a group ambulatory hospital patients. We compared approaches using single respiration-induced modulations on the ECG and PPG signals with approaches fusing the different modulations. Additionally, we investigated whether the presence of both the simultaneously recorded ECG and PPG signals provided a benefit in the overall system performance. Our method outperformed state-of-the-art ECG- and PPG-based algorithms and gave the best results over the whole database with a mean error of 1.8bpm for 1min estimates when using the fused ECG modulations, which was a relative error of 10.3%. No statistically significant differences were found when comparing the ECG-, PPG- and ECG/PPG-based approaches, indicating that the PPG can be used as a valid alternative to the ECG for applications using wearable sensors. While the presence of both the ECG and PPG signals did not provide an improvement in the estimation error, it increased the proportion of windows for which an estimate was obtained by at least 9%, indicating that the use of two simultaneously recorded signals might be desirable in high-acuity cases where an RR estimate is required more frequently.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Respiratory Volumes and Capacities I
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...