Forgotten CBD stent (102 months) with stone-stent complex: A case report
Varsha Barai1, Jagadish Hedawoo2, Sanjay Changole2
1Postgraduate Student, Department of Surgery, Government Medical College, Nagpur, India.
International Journal of Surgery Case Reports
|December 25, 2016
Summary
Retained biliary stents can lead to serious complications like stone formation and infection, causing symptoms such as pain, fever, and jaundice. Timely stent removal is crucial to prevent these adverse effects.
Area of Science:
- Gastroenterology
- Surgical Innovation
- Medical Device Complications
Background:
- Choledocholithiasis, or common bile duct stones, can be managed via endoscopy or surgery.
- Retained foreign bodies, such as biliary stents, can act as a nidus for stone formation, leading to symptoms like pain, fever, and jaundice.
Purpose of the Study:
- To highlight the potential complications associated with retained biliary stents.
- To emphasize the importance of timely stent removal in preventing adverse outcomes.
Main Methods:
- A case presentation of a 60-year-old female patient with cholangitis, common bile duct stones, and a stent in situ.
- Diagnostic imaging (CT scan) revealed a cholangitic abscess, dilated common bile duct, and sludge around the stent.
- Surgical exploration identified a stone at the proximal end of the stent.
Main Results:
- Retained stents, while sometimes asymptomatic, can migrate or form a nidus for stone development.
- Prolonged stent presence can lead to bacterial proliferation, biofilm formation, and calcium bilirubinate precipitation, manifesting as fever, pain, and jaundice.
- The stent-stone complex was successfully treated through both endoscopic and surgical interventions.
Conclusions:
- Biliary stents carry risks including stone formation and infection, necessitating careful monitoring and timely removal.
- Patients should be informed of potential stent-related complications and advised on regular follow-up and adherence to removal schedules, typically around 6 weeks post-insertion.