Related Experiment Videos
Ozone removal capability of a welding fume respirator containing activated charcoal
A R Johnston1, J F Dyrud, Y T Shih
1Occupational Health and Environmental Safety Division, 3M, St. Paul, MN 55144-1000.
Abstract:
Development of air purifying respirators for protection against ozone has been slowed by concerns about oxidation of charcoal and other available sorbents. The suitability of a charcoal sorbent for low concentrations of ozone was evaluated as a part of the development of a half-mask air purifying respirator designed for welding fumes and ozone. Testing of the respirator confirmed that charcoal can be a suitable sorbent for low levels of ozone. Where the respirator is properly selected, fit tested, and worn, respirator use against welding fumes and ozone at concentrations not exceeding 10 times the permissible exposure limit had been recommended.