Influence of continuously evolving transcatheter aortic valve implantation technology on cerebral oxygenation
Ward Eertmans1,2, Cornelia Genbrugge3,4, Tom Fret3
1Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium. ward.eertmans@uhasselt.be.
Abstract:
This study assessed the influence of the evolution in Transcatheter Aortic Valve Implantation technology on cerebral oxygenation. Cerebral oxygenation was measured continuously with Near-Infrared Spectroscopy and compared retrospectively between balloon-expandable, self-expandable and differential deployment valves which were implanted in 12 (34%), 17 (49%) and 6 patients (17%), respectively. Left and right SctO2 values were averaged at four time points and used for analysis (i.e. at baseline, balloon-aortic valvuloplasty, valve deployment, and at the end of the procedure). During balloon-aortic valvuloplasty and valve deployment, cerebral oxygenation decreased in patients treated with balloon or self-expandable valves (balloon-expandable: p = 0.003 and p = 0.002; self-expandable: p < 0.001 and p = 0.003, respectively). The incidence of cerebral desaturations below 80% of baseline was significantly larger in patients treated with balloon-expandable valves (p = 0.001). In contrast, patients who received differential deployment valves never experienced a cerebral desaturation below 80% of baseline. Furthermore, both the incidence and duration below a cerebral oxygenation of 55% was significantly different between balloon and self-expandable valves (p = 0.038 and p = 0.018, respectively). This study demonstrated that Transcatheter Aortic Valve Implantation procedures are associated with significant cerebral desaturations, especially during balloon-aortic valvuloplasty and valve deployment. Moreover, our results showed that latest innovations in Transcatheter Aortic Valve Implantation technology beneficially influenced the adequacy of cerebral perfusion.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...