Design of experiment assisted concurrent enantioseparation of bupropion and hydroxybupropion by high-performance
Nejal M Bhatt1, Vijay D Chavada1, Mallika Sanyal2
1Chemistry Department, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India.
Abstract:
A simple and efficient high-performance thin-layer chromatographic method was developed for chiral separation of rac-bupropion (BUP) and its active metabolite rac-hydroxybupropion (HBUP). Design of experiment (DoE)-based optimization was adopted instead of a conventional trial-and-error approach. The Box-Behnken design surface response model was used and the operating variables were optimized based on 17 trials design. The optimized method involved impregnation of chiral reagent, L(+)-tartaric acid, in the stationary phase with simultaneous addition in the mobile phase, which consisted of acetonitrile : methanol : dichloromethane : 0.50% L-tartaric acid (6.75:1.0:1.0:0.25, v/v/v/v). Under the optimized conditions, the resolution factor between the enantiomers of BUP and HBUP was 6.30 and 9.26, respectively. The limit of detection and limit of quantitation for (R)-BUP, (S)-BUP, (R,R)-HBUP, and (S,S)-HBUP were 9.23 and 30.78 ng spot-1 , 10.32 and 34.40 ng spot-1 , 12.19 and 40.65 ng spot-1 , and 14.26 and 47.53 ng spot-1 , respectively. The interaction of L-tartaric acid with analytes and their retention behavior was thermodynamically investigated using van't Hoff's plots. The developed method was validated as per the International Conference on Harmonization guidelines. Finally, the method was successfully applied to resolve and quantify the enantiomeric content from marketed tablets as well as spiked plasma samples.
More Related Videos
09:12Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Affinity Chromatography
High-Performance Liquid Chromatography: Instrumentation