Arthroscopic fixation with EndoButton for tibial eminence fractures visualised through a proximal superomedial
Hitoshi Sekiya1, Kenzo Takatoku1, Akinori Kimura2
1Department of Orthopaedic Surgery, Shin-Kaminokawa Hospital, Tochigi, Japan.
Abstract:
Most tibial eminence fractures are avulsion fractures of the anterior cruciate ligament (ACL) from its tibial insertion. This study describes a new arthroscopic technique using an additional proximal superomedial portal to visualise the tibial eminence fracture and to fix the fracture with the EndoButton to avoid the risk of fragment breakage. The proximal superomedial portal enables fracture reduction without damage to the intermeniscal ligament. Fixation with the EndoButton is strong enough to allow early rehabilitation with vigorous exercise. All 5 patients achieved bone union; no young patient had growth disturbance of the tibia; all knees were stable with excellent range of motion and negative Lachman and pivot shift tests and no flexion contracture. Arthroscopic fixation with the EndoButton visualised through the proximal superomedial portal is a safe, simple, and secure method for treating tibial eminence fractures, particularly in children with small fragments.
More Related Videos
09:01Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner