Development and comparison of gas chromatography-mass spectrometry techniques for analysis of flame retardants
Jakob Gustavsson1, Lutz Ahrens1, Minh A Nguyen1
1Department of Aquatic Sciences and Assessment, Swedish University of Agricultural Sciences, Box 7050, SE-75007, Uppsala, Sweden.
Abstract:
The restrictions on the use of legacy flame retardants (FRs) have increased the need of alternative FRs to comply with fire safety legislations. In this study, the feasibility of three different gas chromatography-mass spectrometry (GC-MS) techniques were investigated for the analysis of 102 legacy and alternative FRs including polybrominated diphenyl ethers (PBDEs, n=27), halogenated FRs (HFRs, containing bromine and/or chlorine, n=46), and organophosphorous FRs (OPFRs, n=29). The tested techniques included GC-single MS with (i) electon impact (EI) ionization and (ii) negative chemical ionization (NCI), and (iii) GC-tandem MS (MS/MS) with EI ionization. Out of the tested FRs, 90 could be detected under the used conditions on at least one of the three instrument setups. Later experiments included a selection of these FRs. For the majority of tested PBDEs (5 out of 6) and HFRs (24 out of 26), EI-MS/MS provided the highest detectability (i.e. the lowest detection limits), while for most tested OPFRs (8 out of 13), EI-MS performed better. The influence of matrix components on the analysis of FRs (n=45) was investigated by analyzing a fortified surface water sample with the technique with the lowest selectivity, EI-MS. Both peak enhancement and suppression were observed, and significant correlations between matrix effects and several physico-chemical properties (e.g., retention time and boiling point) were found for PBDEs. In a separate clean-up experiment using natural water spiked with legacy and alternative FRs (n=30), alumina provided the highest mean recovery (90%) in comparison to acidified silica (67%) and Florisil (78%). This study provides new knowledge on analysis of FRs including a wide range of alternative FRs, and it will aid in the efforts of FR monitoring in the environment.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Flame Photometry: Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...