Related Experiment Video
Updated: Mar 9, 2026

Ultrasonographic Assessment During Cardiopulmonary Resuscitation
Published on: October 24, 2020
Evaluation of new two-thumb chest compression technique for infant CPR performed by novice physicians. A randomized,
Jacek Smereka1, Lukasz Szarpak2, Adam Smereka3
1Department of Emergency Medical Service, Wroclaw Medical University, Wroclaw, Poland.
Background:
The impact of high-quality chest compressions during CPR for the patients' outcome is undisputed, as it is essential for maintaining vital organ perfusion. The aim of our study is to compare the quality of chest compression (CC) and ventilation among the two current standard techniques with our novel "nTTT" technique in infant CPR.
Methods:
In this randomized crossover, manikin trial, participants performed CCs using three techniques in a randomized sequence: standard two finger technique (TFT); standard two thumb technique (TTHT), and the 'new two-thumb technique' (nTTT). The novel method of CCs in an infant consists in using two thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist.
Results:
Median depth compression using the distinct chest compression techniques varied and amounted to 26 [IQR, 25-28] mm for TFT, and 39 [IQR, 39-39] mm for TTHT as well as for nTTT. Best percentage of fully released compressions were received using TFT (100[100-100] %), then in the case of nTTT (99[98-100] %), and the worst in situation where TTHT (18[14-19] %). was used. The fastest chest compression rate was achieved with TFT (134[IQR, 129-135]/min) and the slowest when using nTTT (109 [IQR, 105-111]/min).
Conclusions:
We found that our new nTTT technique's performance, in terms of compression depth, hands-off time, and ventilation quality, is comparable to the current standards. Based on our findings of this initial manikin study, the nTTT technique is superior to TFT in many of parameters that are vital to a quality chest compression during pediatric CPR.
More Related Videos
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiopulmonary Resuscitation III: AED Use