Abstract:
The purpose of this publication is to describe the intraoperative experience along with long-term safety and efficacy of the second-generation baroreflex activation therapy (BAT) system in patients with heart failure (HF) and reduced ejection fraction HF (HFrEF). In a randomized trial of New York Heart Association Class III HFrEF, 140 patients were assigned 1:1 to receive BAT plus medical therapy or medical therapy alone. Procedural information along with safety and efficacy data were collected and analyzed over 12 months. Within the cohort of 71 patients randomized to BAT, implant procedure time decreased with experience, from 106 ± 37 minutes on the first case to 83 ± 32 minutes on the third case. The rate of freedom from system- and procedure-related complications was 86% through 12 months, with the percentage of days alive without a complication related to system, procedure, or underlying cardiovascular condition identical to the control group. The complications that did occur were generally mild and short-lived. Overall, 12 months therapeutic benefit from BAT was consistent with previously reported efficacy through 6 months: there was a significant and sustained beneficial treatment effect on New York Heart Association functional Class, quality of life, 6-minute hall walk distance, plasma N-terminal pro-brain natriuretic peptide, and systolic blood pressure. This was true for the full trial cohort and a predefined subset not receiving cardiac resynchronization therapy. There is a rapid learning curve for the specialized procedures entailed in a BAT system implant. BAT system implantation is safe with the therapeutic benefits of BAT in patients with HFrEF being substantial and maintained for at least 1 year.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
06:30Complete and Partial Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhagic Shock
Published on: May 19, 2022
Related Concept Videos
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Heart Failure V: Medical Management
Heart Failure VI: Adjunct Therapies
Heart Failure Drugs: β-Blockers
Heart Failure II: Pathophysiology
Aortic Regurgitation III: Medical Management