Tracheostomy in the Intensive Care Unit: a University Hospital in a Developing Country Study
Mohammad Waheed El-Anwar1, Ahmad Abdel-Fattah Nofal1, Mohammad A El Shawadfy1
1Department of Otorhinolaryngology, Head and Neck Surgery, School of Medicine, Zagazig University, Zagazig, Egypt.
Abstract:
Introduction Tracheostomy is the commonest surgical procedure in intensive care units (ICUs). It not only provides stable airway and facilitates pulmonary toilet and ventilator weaning, but also decreases the direct laryngeal injury of endotracheal intubation, and improves patient comfort and daily living activity. Objective The objective of this study is to assess the incidence, indications, timing, complications (early and late), and the outcome of tracheostomy on patients in the intensive care units (ICU) at a university hospital in a developing country. Methods This study is an observational prospective study. It was performed at the otolaryngology department and ICU new surgery hospital on 124 ICU admitted patients. We collected patients' demographic records, cause of admission, indications of tracheostomy, mechanical ventilation, and duration of ICU stay. We also gathered patientś tracheostomy records including the incidence, timing, technique, type, early and late complications, and outcome. All tracheostomized patients received follow-up for 12 months. Results The indication for tracheostomy in ICU patients was mostly prolonged intubation (80.5%), followed by diaphragmatic paralysis (19.5%). All tracheostomies were done by the open approach technique. Tracheostomy for prolonged intubation was done within 17 to 26 days after intubation with a mean of 19.4 ± 2.07 days. Complications after tracheostomy were 13.9% tracheal stenosis and 25% subglottic stenosis. Conclusion Prolonged endotracheal intubation is the man indication of tracheostomy, performed after two weeks of intubation. Although there were no major early complications, laryngotracheal stenosis is still a challenging sequel for tracheostomy that needs to be investigated to be prevented.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:43Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...