Related Experiment Video
Updated: Mar 9, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation
S Lumetti1, G Ghiacci1, G M Macaluso1
1Centro Universitario di Odontoiatria, SBiBiT, Università degli Studi di Parma, Parma, Italy.
Abstract:
Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.
Related Concept Videos
Oral Drug Delivery Systems: Delayed-Release Systems
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of...
Oral Drug Delivery Systems: Introduction
Oral Drug Delivery Systems: Continuous-Release Systems