Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

7.3K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
7.3K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

2.8K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.8K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

1.9K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.9K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

1.3K
Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.3K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

14.7K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Mapping Double-Bond Positional Isomers of Phosphatidylcholines in Zebrafish Using OzMALDI Mass Spectrometry Imaging.

Journal of the American Society for Mass Spectrometry·2026
Same author

ATML1-GIR1-TPL/TPR transcriptional repression module controls glucosinolates and giant cells in <i>Arabidopsis thaliana</i> sepals.

bioRxiv : the preprint server for biology·2026
Same author

Beyond identification: inferring physical activity from fingerprint lipids using machine learning.

Analytical methods : advancing methods and applications·2026
Same author

Optimising the induction of inflammation within preterm infant-derived intestinal epithelial organoids.

Npj gut and liver·2026
Same author

Advanced Tissue Imprinting With Pneumatic Press for Mass Spectrometry Imaging of Plant Tissues.

Journal of mass spectrometry : JMS·2025
Same author

Improving Metabolite Annotations in On-Tissue Chemical Derivatization Mass Spectrometry Imaging by Functional Group Filtering and Hydrogen-Deuterium Exchange.

Journal of the American Society for Mass Spectrometry·2025

Related Experiment Video

Updated: Mar 9, 2026

Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI
10:47

Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI

Published on: March 24, 2016

10.0K

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical

Adam D Feenstra1,2, Maria Emilia Dueñas1,2, Young Jin Lee3,4

  • 1Department of Chemistry, Iowa State University, Ames, IA, 50011, USA.

Journal of the American Society for Mass Spectrometry
|January 5, 2017
PubMed
Summary

Researchers enhanced laser optics for matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI), achieving ~4 μm spot size for 5 μm resolution. This advancement enables detailed chemical mapping at cellular levels with adjustable resolution.

Keywords:
Laser spot sizeMALDIMaizeMass spectrometry imagingOpticsResolutionRoot

More Related Videos

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
09:38

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Published on: November 26, 2013

14.7K
Molecular Imaging of Human Brain Organoids Using Mass Spectrometry
08:04

Molecular Imaging of Human Brain Organoids Using Mass Spectrometry

Published on: September 27, 2024

1.4K

Related Experiment Videos

Last Updated: Mar 9, 2026

Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI
10:47

Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI

Published on: March 24, 2016

10.0K
Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
09:38

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Published on: November 26, 2013

14.7K
Molecular Imaging of Human Brain Organoids Using Mass Spectrometry
08:04

Molecular Imaging of Human Brain Organoids Using Mass Spectrometry

Published on: September 27, 2024

1.4K

Area of Science:

  • Analytical Chemistry
  • Biotechnology
  • Microscopy

Background:

  • High-spatial resolution mass spectrometry imaging (MSI) is vital for analyzing chemical distributions at cellular and subcellular scales.
  • Previous matrix-assisted laser desorption ionization-MSI (MALDI-MSI) systems had limitations in achievable spatial resolution.

Purpose of the Study:

  • To improve the laser optical system for MALDI-MSI to achieve higher spatial resolution.
  • To enable flexible and rapid adjustment of laser spot size for multi-resolution imaging.

Main Methods:

  • Implemented a new laser optics system incorporating spatial filtering, beam expansion, and reduced focal length.
  • Developed a modular design allowing quick interchange of beam expanders to modify laser spot size (~4 μm, ~7 μm, ~45 μm).
  • Applied the multi-resolution system to maize root tissue, analyzing imaging quality and signal sensitivity at 5, 10, and 50 μm resolutions.

Main Results:

  • Achieved a practical laser spot size of ~4 μm, enabling 5 μm resolution MALDI-MSI without oversampling.
  • Demonstrated rapid (under 5 minutes) switching between multiple spatial resolutions (5, 10, 50 μm).
  • Observed differences in imaging quality, signal sensitivity, and depth of focus across resolutions.

Conclusions:

  • The improved laser optics significantly enhance MALDI-MSI capabilities for high-resolution chemical mapping.
  • The system's adaptability allows for optimized data acquisition based on specific research needs.
  • This advancement facilitates more detailed investigations of biological samples at the microscale.