Related Experiment Video
Updated: Mar 9, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Retention prediction of low molecular weight anions in ion chromatography based on quantitative structure-retention
Soo Hyun Park1, Paul R Haddad1, Mohammad Talebi1
1Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, 7001, Australia.
Abstract:
Quantitative Structure-Retention Relationships (QSRRs) represent a popular technique to predict the retention times of analytes, based on molecular descriptors encoding the chemical structures of the analytes. The linear solvent strength (LSS) model relating the retention factor, k to the eluent concentration (log k=a-blog [eluent]), is a well-known and accurate retention model in ion chromatography (IC). In this work, QSRRs for inorganic and small organic anions were used to predict the regression parameters a and b in the LSS model (and hence retention times) for these analytes under a wide range of eluent conditions, based solely on their chemical structures. This approach was performed on retention data of inorganic and small organic anions from the "Virtual Column" software (Thermo Fisher Scientific). These retention data were recalibrated via a "porting" methodology on three columns (AS20, AS19, and AS11HC), prior to the QSRR modeling. This provided retention data more applicable on recently produced columns which may exhibit changes of column behavior due to batch-to-batch variability. Molecular descriptors for the analytes were calculated with Dragon software using the geometry-optimized molecular structures, employing the AM1 semi-empirical method. An optimal subset of molecular descriptors was then selected using an evolutionary algorithm (EA). Finally, the QSRR models were generated by multiple linear regression (MLR). As a result, six QSRR models with good predictive performance were successfully derived for a- and b-values on three columns (R2>0.98 and RMSE<0.11). External validation showed the possibility of using the developed QSRR models as predictive tools in IC (Qext(F3)2>0.7 and RMSEP<0.4). Moreover, it was demonstrated that the obtained QSRR models for the a- and b-values can predict the retention times for new analytes with good accuracy and predictability (R2 of 0.98, RMSE of 0.89min, Qext(F3)2 of 0.96 and RMSEP of 1.18min).
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Methods: Terminology
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Analyte Adsorption and Distribution
Chemical Ionization (CI) Mass Spectrometry