Related Experiment Video
Updated: Mar 9, 2026

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
Percutaneous retrieval of a fractured dialysis catheter using a balloon
Su Nam Lee1, Min Seop Jo2, Ki-Dong Yoo1
1Department of Internal Medicine, St. Vincent's Hospital, The Catholic University of Korea, Suwon - South Korea.
Abstract:
Intravascular foreign bodies can cause serious complications and catheter fracture with or without embolization is a rare, serious event. Intravascular fragments from broken catheters can be retrieved percutaneously or surgically, and should be removed as soon as possible to prevent further lethal complications. A gooseneck loop snare is the most popular device for endovascular retrieval of intravascular foreign bodies. Herein, we present the first report of successful percutaneous retrieval of a fractured catheter using a balloon.
More Related Videos
Related Concept Videos
Hemodialysis II: Procedure and Complications
Peritoneal Dialysis I: Introduction and Procedure
Hemodialysis I: Introduction
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy