Related Experiment Video
Updated: Mar 9, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Proportional Insulin Infusion in Closed-Loop Control of Blood Glucose
Johan Grasman1, Hannah L Callender2, Marco Mensink3
1Biometris, Wageningen University and Research Centre, Wageningen, The Netherlands.
Abstract:
A differential equation model is formulated that describes the dynamics of glucose concentration in blood circulation. The model accounts for the intake of food, expenditure of calories and the control of glucose levels by insulin and glucagon. These and other hormones affect the blood glucose level in various ways. In this study only main effects are taken into consideration. Moreover, by making a quasi-steady state approximation the model is reduced to a single nonlinear differential equation of which parameters are fit to data from healthy subjects. Feedback provided by insulin plays a key role in the control of the blood glucose level. Reduced β-cell function and insulin resistance may hamper this process. With the present model it is shown how by closed-loop control these defects, in an organic way, can be compensated with continuous infusion of exogenous insulin.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Oral Hypoglycemic Agents: Glinides
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...