Related Experiment Video
Updated: Mar 9, 2026

11:13
Covalent Immobilization of Proteins for the Single Molecule Force Spectroscopy
Published on: August 20, 2018
11.7K
Improved Force Spectroscopy Using Focused-Ion-Beam-Modified Cantilevers
J K Faulk1, D T Edwards1, M S Bull1
1JILA, National Institute of Standards and Technology and University of Colorado, Boulder, CO, United States.
Methods in Enzymology
|January 8, 2017
Summary
Researchers improved atomic force microscopy (AFM) data quality by modifying cantilevers with focused-ion-beam (FIB) technology. This method enhances force precision and stability, crucial for biophysical studies like protein folding.
Area of Science:
- Biophysics
- Materials Science
- Nanotechnology
Background:
- Atomic force microscopy (AFM) is essential for biophysical research, particularly in force-spectroscopy studies of protein folding and ligand interactions.
- Current AFM data quality is often limited by the mechanical properties of commercial cantilevers, presenting a tradeoff between force stability and precision.
- Existing limitations hinder the accuracy and resolution of AFM-based measurements in sensitive biological applications.
Purpose of the Study:
- To present a novel method for enhancing AFM cantilever performance through focused-ion-beam (FIB) modification.
- To overcome the inherent limitations of commercial cantilevers, improving both force precision and stability without sacrificing temporal resolution.
- To provide an accessible and customizable protocol for fabricating improved AFM cantilevers for diverse biophysical applications.
Main Methods:
- Focused-ion-beam (FIB) modification of commercially available AFM cantilevers.
- Reduction of cantilever hydrodynamic drag and stiffness through controlled FIB milling.
- Selective retention of gold coating at the cantilever's free end to enhance stability.
Main Results:
- Achieved sub-pN force precision over five decades of bandwidth (0.01–1000 Hz) using modified short cantilevers (L=40μm), with minimal impact on temporal resolution (~75μs).
- Demonstrated improved force precision and stability in ultrashort cantilevers (L=9μm), maintaining 1-μs-scale temporal resolution.
- Eliminated underdamped high-frequency motion in ultrashort cantilevers, preventing unwanted force oscillations on molecules.
Conclusions:
- FIB modification offers a viable method to significantly enhance AFM cantilever performance, addressing critical limitations in force precision and stability.
- The protocol is accessible to researchers, with undergraduate students capable of fabricating modified cantilevers efficiently.
- FIB-modified cantilevers are expected to advance a wide range of AFM-based biophysical research by providing higher quality data.
Keywords:
Atomic force microscopyCantilever dynamicsFocused-ion-beam modificationProtein foldingSingle-molecule biophysicsSingle-molecule force spectroscopy