Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures:
T Diekhoff1, K G Hermann1, M Pumberger2
1Department of Radiology, Charité - Universitätsmedizin Berlin Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Berlin, Germany.
Objectives:
Dual-energy computed tomography (DECT) is a recent development for detecting bone marrow edema (BME) in patients with vertebral compression fractures. The aim of this pilot study was to determine the reliability of single-source DECT in detecting vertebral BME using magnetic resonance imaging (MRI) as standard of reference.
Materials And Methods:
Nine patients with radiographic thoracic or lumbar vertebral compression fractures underwent both, DECT on a 320-row single-source scanner and 1.5T MRI. Virtual non-calcium (VNC) images were reconstructed from the DECT volume datasets. Three blinded readers independently scored images for the presence of BME. Only vertebrae with loss of height in radiography (target vertebrae) were included in the analysis. A vertebra was counted as positive if two readers agreed on the presence of BME. Cohen's kappa was calculated for interrater comparison. Intervertebral ratios of target and the reference vertebra were compared for CT attenuation and MR signal intensity in a reference vertebra using Spearman correlation. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated.
Results:
Fourteen target vertebrae with a radiographic height loss were identified; eight of them showed BME on MRI, while DECT identified BME in 7 instances. There were no false positive virtual non-calcium images, resulting in a sensitivity of 0.88 (0.75-1.0 among all readers) and specificity of 1.0 (0.81-1.0). Interrater agreement was inferior for DECT (κ=0.63-0.89) compared to MRI (κ=0.9-1.0). Intervertebral ratio in VNC images strongly correlated with short-tau inversion recovery (r=0.87) and inversely with T1 (-0.89). SNR (0.2+/- 0.2 in VNC and 16.7+/- 7.3 in STIR) and CNR (0.2+/- 0.3 and 7.1+/- 6.3) values were inferior in VNC.
Conclusions:
Detecting BME with single-source DECT is feasible and allows detection of vertebral compression fractures with reasonably high sensitivity and specificity. However, image quality of VNC reconstructions has to be improved to achieve better interrater agreement. Nonetheless, DECT might accelerate the diagnostic work-flow in patients with vertebral compression fractures in the future and reduce the number of additional MRI examinations.
More Related Videos
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Radiological Investigation I: X-ray and CT