Fresh-Frozen Plasma: Ordering Patterns and Utilization in the Operating Rooms of a Tertiary Referral Hospital
Matthew J Meyer1, Walter H Dzik, Wilton C Levine
1From the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts.
Background:
Blood product transfusion is the most commonly performed hospital procedure. Intraoperative blood product utilization varies between institutions and anesthesiologists. In the United States in 2011, nearly 4 million plasma units were transfused.
Methods:
A retrospective analysis of intraoperative plasma ordering patterns and utilization (thawing and transfusing) was performed at a tertiary, academic hospital between January 2015 and March 2016.
Results:
Over 15 months, 46,002 operative procedures were performed. In 1540 of them, plasma was thawed or transfused: 8297 plasma units were thawed and 3306 of those units were transfused. These 3306 plasma units were transfused in 749 cases with a median of 2 plasma units (interquartile range, 2-4) transfused. The percentage of average monthly procedures with plasma thawed and none transfused was 51.3% (confidence interval, 49.0%-53.6%). The cardiac surgery service requested the greatest number of plasma units to be thawed (2143) but only transfused 712 (33.2%) of them. Of all plasma units not transfused, 45% were generated by procedures with 1 to 4 units of plasma thawed; 95.7% of these units were thawed as even integers (ie, 2, 4).
Conclusions:
For operative procedures, far more plasma was thawed than was transfused and this practice occurred across surgical specialties and anesthesiologists. Considering the plasma that was not transfused, 45% occurred in procedures with 4 or fewer units of plasma requested suggesting these low-volume requests were a primary source of potential waste. Further studies are needed to examine associations between plasma utilization and clinical outcomes.