Comparing Fracture Resistance and the Time Required for Two Different Fiber Post Removal Systems
Seda Aydemir1, Göze Arukaslan1, Serkan Sarıdağ2
1Department of Endodontics, Kocaeli University Faculty of Dentistry, Kocaeli, Turkey.
Purpose:
To compare two fiber post removal techniques in terms of fracture resistance and time required for post removal.
Materials And Methods:
Post space was prepared to a 9-mm depth in each root canal. The roots were randomly divided into three groups of 15 specimens each. D.T. Light-Posts were cemented in all groups. In group 1, fiber posts were removed using the D.T. Light-Post-removal kit; in group 2, Start-X stainless-steel ultrasonic tips were used. In group 3, fiber posts were left without removal (the control group). For all groups, fracture resistance (N) value was measured and recorded using a universal testing machine. Times required for fiber post removal were also recorded for the two study groups.
Results:
There was no significant difference between the control and removal kit groups for fracture resistance values (p = 0.233). The fracture resistance value of the ultrasonic group was found to be significantly lower than that of the control group (p = 0.001) as well as that of the removal kit group (p = 0.032). The fiber post removal time for the ultrasonic group was significantly longer than that for the removal kit group (p < 0.001).
Conclusion:
Compared to the removal kit, removal of the fiber posts with an ultrasonic tip decreases the fracture resistance of the roots, although significantly more time is required.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Fiber Reinforced Concrete
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...