Related Experiment Video
Updated: Mar 9, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Identifying Predictors of Central Sleep Apnea/Cheyne-Stokes Breathing in Chronic Heart Failure: a Pathophysiological
Aneliya I Draganova1, Kiril V Terziyski1, Stefan S Kostianev1
1Department of Pathophysiology, Faculty of Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria
Abstract:
Chronic heart failure (CHF) is a major health problem associated with increased mortality, despite modern treatment options. Central sleep apnea (CSA)/Cheyne-Stokes breathing (CSB) is a common and yet largely under-diagnosed co-morbidity, adding significantly to the poor prognosis in CHF because of a number of acute and chronic effects, including intermittent hypoxia, sympathetic overactivation, disturbed sleep architecture and impaired physical tolerance. It is characterized by repetitive periods of crescendo-decrescendo ventilatory pattern, alternating with central apneas and hypopneas. The pathogenesis of CSA/CSB is based on the concept of loop gain, comprising three major components: controller gain, plant gain and feedback gain. Laboratory polysomnography, being the golden standard for diagnosing sleep-disordered breathing (SDB) at present, is a costly and highly specialized procedure unable to meet the vast diagnostic demand. Unlike obstructive sleep apnea, CSA/CSB has a low clinical profile. Therefore, a reliable predictive system is needed for identifying CHF patients who are most likely to suffer from CSA/CSB, optimizing polysomnography use. The candidate predictors should be standardized, easily accessible and low-priced in order to be applied in daily medical routine. The present review focuses on a pathophysiological approach to the selection of some predictors based on parameters reflecting the etiology, the pathogenesis and the consequences of CSA/CSB in CHF.
More Related Videos
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Heart Failure VI: Adjunct Therapies
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory Volumes and Capacities I