Related Experiment Video For Improved iodine contrast
Updated: Mar 9, 2026

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Noise-optimized monoenergetic post-processing improves visualization of incidental pulmonary embolism in cancer
Jakob Weiss1, Mike Notohamiprodjo2, Malte Bongers2
1Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany. Jakob.Weiss@uni-tuebingen.de.
Purpose:
To evaluate noise-optimized monoenergetic postprocessing of dual-energy CT (DE-CT) on image quality in patients with incidental pulmonary embolism in single-pass portal-venous phase CT (CTpv).
Materials And Methods:
20 Consecutive patients with incidental pulmonary embolism in contrast-enhanced oncological follow-up DE-CTpv examination were included in this study. Images were acquired with a 3rd generation DE-CT system in DE mode (100/Sn150 kV) and activated tube current modulation 90 s after contrast agent administration. Subsequently, virtual monoenergetic images (MEI+) were reconstructed at five different keV levels (40, 55, 70, 85, 100) and compared to the standard linearly blended (M_0.8) CTpv images. Image quality was assessed qualitatively (vascular contrast and detectability of embolism, image noise, iodine influx artifact; two independent readers; 5-point Likert scale; 5 = excellent) and quantitatively by calculating signal-to-noise (SNR) and contrast-to-noise ratios (CNR).
Results:
Highest vessel contrast and highest detectability of embolism were observed in MEI+ at 40 keV (4.7 ± 0.4) and 55 keV (4.2 ± 0.6) with significant differences as compared to CTpv (3.6 ± 0.5) and high keV reconstructions (70, 85, 100; p ≤ 0.01). Image noise significantly increased at 40 keV MEI+ compared to all other MEI+ reconstructions and CTpv (p < 0.001). SNR and CNR calculations were highest at 40 keV MEI+ followed by 55 keV and CTpv with significant differences to high keV MEI+ (85-100).
Conclusions:
Computed MEI+ at low keV levels allow for improved vessel contrast and visualisation of incidental pulmonary embolism in patients with portal-venous phase CT scans by substantially increasing CNR and SNR.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography