Background:
Flexible bronchoscopy is pivotal for the diagnosis of most respiratory diseases. A flexible bronchoscopy unit (FBU) was created in 2008 in the Preah Kossamak university hospital (Phnom Penh, Cambodia) through a cooperation program between a French and a Cambodian team. In 2009 we conducted an assessment of the compliance of the FBU to international standards and found that most of French and British guidelines were fully applied or adapted to local practice. The aim of the current work was to assess FBU again 6 years later, in order to determine if compliance to international guidelines was sustainable.
Methods:
The 2015 evaluation was conducted identically to 2009. All recommendation items from the French and the British Thoracic Societies guidelines were assessed individually. Each recommendation was assigned a status expressing the level at which it was respected in Cambodia: applied, adapted, not applied and not evaluable. An endoscope microbial sampling was performed as recommended by the French Ministry of Health.
Results:
Between 2009 and 2015, the pattern of international recommendations in the Cambodian FBU did not change. Notably the rates of applied French evaluable recommendations remained stable: respectively 58% vs 57%. Main changes in French guidelines occurred in adapted items that became applied (n = 5/15) while 4 previously adapted/applied items became not applied. Furthermore, all microbial analyses showed sterile results.
Conclusions:
Our results show that implementation of a high quality FBU in a least-developed country is feasible. In addition, the performance is maintained in the long-term.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
COPD: Management Using Bronchodilators and Corticosteroids
Methods Of Healthcare Delivery System
Managed Care System:
The managed care system is designed to control the cost while maintaining the quality of care. The patient's care from admission to discharge is planned by the primary care provider or the case manager, also known as the gatekeeper. In a managed care system, the number of care providers is...