Sensorless Modeling of Varying Pulse Width Modulator Resolutions in Three-Phase Induction Motors

Matthew David Marko1, Glenn Shevach1

  • 1Naval Air Warfare Center Aircraft Division, Joint-Base McGuire-Dix-Lakehurst, Lakehurst NJ 08733, United States of America.

Plos One
|January 12, 2017
PubMed

Related Concept Videos

Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
638
Generation of Three-Phase Voltage01:21

Generation of Three-Phase Voltage

A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
898
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
768
Simplified Synchronous Machine Model01:30

Simplified Synchronous Machine Model

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
843
Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
678
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
691