Related Experiment Video
Updated: Mar 8, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Midterm Radiographic and Functional Outcomes of the Anterior Subcutaneous Internal Pelvic Fixator (INFIX) for Pelvic
Rahul Vaidya1, Adam Jonathan Martin, Matthew Roth
1*4G University Health Center, Detroit Receiving Hospital, Detroit Medical Center, Wayne State University, Detroit, MI; †Wayne State University School of Medicine, Detroit, MI; ‡Detroit Medical Center, Wayne State University, Detroit, MI; and §Detroit Medical Center, Michigan State University, Detroit, MI.
Objective:
To describe our experience using the anterior internal pelvic fixator (INFIX) for treating pelvic ring injuries.
Design:
Case Series.
Setting:
Level 1 Trauma Center.
Patients:
Eighty-three patients with pelvic ring injuries were treated with INFIX. Follow-up average was 35 months (range 12-80.33).
Intervention:
Surgical treatment of pelvic ring injuries included reduction, appropriate posterior fixation, and INFIX placement.
Outcome Measurements:
Reduction using the pelvic deformity index and pubic symphysis widening, Majeed functional scores, complications; infection, implant failure, heterotopic ossification (HO), nerve injury, and pain.
Results:
All patients healed in an appropriate time frame (full weight bearing 12 weeks postoperation). The average pelvic deformity index reduction (injury = 0.0420 ± 0.0412, latest FU = 0.0254 ± 0.0243) was 39.58%. The average reduction of pubic symphysis injuries was 56.92%. The average Majeed score of patients at latest follow-up was 78.77 (range 47-100). Complications were 3 infections, 1 case of implant failure, 2 cases implantation too deep, 7 cases of lateral femoral cutaneous nerve irritation, and 3 cases of pain associated with the device. HO was seen in >50% of the patients, correlated with increased age (P < 0.007), injury severity score (P < 0.05) but only 1 case was symptomatic.
Conclusions:
The pelvic injuries had good functional and radiological outcomes with INFIX and the appropriate posterior fixation. The downside is removal requiring a second anesthetic, there is a learning curve, HO often occurs, the lateral femoral cutaneous nerve may get irritated which often resolves once the implants are removed. Surgery-specific implants need to be developed.
Level Of Evidence:
Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022