Influence of wall thickness and diameter on arterial shear wave elastography: a phantom and finite element study
Elira Maksuti1, Fabiano Bini, Stefano Fiorentini
1Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57 Stockholm, Sweden. Department of Clinical Physiology, Karolinska Institutet, SE-17176 Stockholm, Sweden.
Abstract:
Quantitative, non-invasive and local measurements of arterial mechanical properties could be highly beneficial for early diagnosis of cardiovascular disease and follow up of treatment. Arterial shear wave elastography (SWE) and wave velocity dispersion analysis have previously been applied to measure arterial stiffness. Arterial wall thickness (h) and inner diameter (D) vary with age and pathology and may influence the shear wave propagation. Nevertheless, the effect of arterial geometry in SWE has not yet been systematically investigated. In this study the influence of geometry on the estimated mechanical properties of plates (h = 0.5-3 mm) and hollow cylinders (h = 1, 2 and 3 mm, D = 6 mm) was assessed by experiments in phantoms and by finite element method simulations. In addition, simulations in hollow cylinders with wall thickness difficult to achieve in phantoms were performed (h = 0.5-1.3 mm, D = 5-8 mm). The phase velocity curves obtained from experiments and simulations were compared in the frequency range 200-1000 Hz and showed good agreement (R 2 = 0.80 ± 0.07 for plates and R 2 = 0.82 ± 0.04 for hollow cylinders). Wall thickness had a larger effect than diameter on the dispersion curves, which did not have major effects above 400 Hz. An underestimation of 0.1-0.2 mm in wall thickness introduces an error 4-9 kPa in hollow cylinders with shear modulus of 21-26 kPa. Therefore, wall thickness should correctly be measured in arterial SWE applications for accurate mechanical properties estimation.
More Related Videos
09:32Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
09:58Assessing Collagen and Elastin Pressure-dependent Microarchitectures in Live, Human Resistance Arteries by Label-free Fluorescence Microscopy
Published on: April 9, 2018
Related Concept Videos
Thin-Walled Hollow Shafts
Unsymmetric Loading of Thin-Walled Members: Problem Solving
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
Elastic Strain Energy for Shearing Stresses
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity