Related Experiment Video
Updated: Mar 8, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Reliability of orthostatic beat-to-beat blood pressure tests: implications for population and clinical studies
C Finucane1, G M Savva2, R A Kenny3
1Department of Medical Physics and Bioengineering, Mercer's Institute for Successful Ageing, St. James's Hospital, Dublin, Ireland. cfinucane@stjames.ie.
Objective:
To assess the test-retest reliability of orthostatic beat-to-beat blood pressure responses to active standing and related clinical definitions of orthostatic hypotension.
Methods:
A random sample of community-dwelling older adults from the pan-European Survey of Health, Ageing and Retirement in Europe, Ireland underwent a health assessment that mimicked that of the Irish Longitudinal Study on Ageing. An active stand test was performed using continuous blood pressure measurements. Participants attended a repeat assessment 4-12 weeks after the initial measurement. A mixed-effects regression model estimated the reliability and minimum detectable change while controlling for fixed observer and time of day effects.
Results:
A total of 125 individuals underwent repeat assessment (mean age 66.2 ± 7.5 years; 55.6% female). Mean time between visits was 84.3 ± 23.3 days. There was no significant mean difference in heart rate or blood pressure recovery variables between the first and repeat assessments. Minimum detectable change was noted for changes from resting values in systolic blood pressure (26.4 mmHg) and diastolic blood pressure (13.7 mmHg) at 110 s and for changes in heart rate (10.9 bpm) from resting values at 30 s after standing. Intra-class correlation values ranged from 0.47 for nadir values to 0.80 for heart rate and systolic blood pressure values measured 110 s after standing.
Conclusion:
Continuous orthostatic beat-to-beat blood pressure and related clinical definitions show low to moderate reliability and substantial natural variation over a 4-12-week period. Understanding variation in measures is essential for study design or estimating the effects of orthostatic hypotension, while clinically it can be used when evaluating longer term treatment effects.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure