Related Experiment Video
Updated: Mar 8, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Determination of Traces of Pb, Cu and Cd in Seawater around Thane Creek by Anodic Stripping Voltammetry Method
Sukanta Maity1, S K Sahu1, G G Pandit2
1Environmental Monitoring and Assessment Section, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.
Abstract:
Trace metals (Pb, Cu and Cd) in seawater samples were pre-concentrated for the simultaneous quantitative determination using solvent extraction procedure in the presence of ammonium pyrrolidine dithiocarbamate (APDC) as complexing agent and methyl isobutyl ketone (MIBK) as organic phase and acid exchange back - extraction followed by its determination by Differential Pulse Anodic Stripping Voltammetry (DPASV). Concentrations of Pb, Cu and Cd vary from 3.0 to 9.44 ng/mL, 12.7 to 28.6 ng/mL and 0.31 to 1.21 ng/mL respectively in seawater samples collected from different locations across Thane Creek area, Mumbai, India. Pb, Cu, Cd concentration were observed to be higher in the eastern side of the Thane Creek as it is covered by various industries.