Related Experiment Video
Updated: Mar 8, 2026

Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
Measurement of electrocardiograms in a bath through tap water utilizing capacitive coupling electrodes placed outside
Kosuke Motoi1, Yasuhiro Yamakoshi2, Takehiro Yamakoshi3
1Shizuoka Institute of Science and Technology, 2200-2 Toyosawa, Fukuroi, 437-8555, Japan. motoi.kosuke@sist.ac.jp.
Background:
Taking a bath sometimes poses a risk for subjects with chronic cardiopulmonary disorders, due to the thermal effect and water pressure on his/her body. The ECG measurement would be helpful for the early recognition of abnormal cardiac beats and respiratory conditions. This paper describes a new attempt to improve on previous bathtub ECG measurement techniques that had electrodes placed inside the bathtub that were intrusive to the subjects' bathing experience. This study is concerned with the initial development of a method to measure an electrocardiogram (ECG) through tap water without conscious awareness of the presence of electrodes that are placed outside the bathtub wall.
Methods:
A configuration of capacitive coupling electrodes placed outside the bathtub was designed so that the electrodes could be hidden. The capacitive coupling was made from the electrodes to the water through the bathtub wall. Two electrodes with an active shielding amplifier covered further by an electromagnetic shield were fixed to the outside surface of the bathtub wall, near the bather's right scapula and left foot. The potential difference between these two electrodes, similar to the bipolar lead-II ECG, was amplified to obtain raw signals inclusive of ECG/QRS components. Respiration intervals were also derived from ECG/RR intervals. Comparison experiments between this bathtub method and conventional direct methods with spot-electrodes and a chest-band sensor were made using 10 healthy male volunteers (22.2 ± 0.98 years).
Results:
The ECG signal was detectable through tap water as well as water with differing conductivity resulting from mixing bathwater additives with the water. ECG signals and respiration curves derived from ECG/RR intervals were successfully obtained in all subjects. The intervals of the ECG/RR and respiration obtained by the bathtub system and by the direct method were respectively agreed well with each other.
Conclusion:
The ECG signal, in particular ECG/QRS components, were successfully detected utilizing capacitive coupling electrodes placed outside the bathtub wall. Also, the ECG/RR and respiration intervals were determined with reasonable accuracy as compared with the conventional direct methods.
More Related Videos
05:57Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
07:43A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
Related Concept Videos
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Interfacial Electrochemical Methods: Overview
Bode Plots Construction
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes