High performance liquid chromatography analysis of 100-nm liposomal nanoparticles using polymer-coated, silica
Naoki Itoh1, Arato Kimoto2, Eiichi Yamamoto3
1Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
Abstract:
Recently, nanoparticles have garnered considerable attention, and the demand for a rapid and simple method for their analysis has increased accordingly. The bimodal pores (few μm- and few tens nm-sized pores) of monolithic columns were thought to be suitable for the separation of nanoparticles and small molecules; however, the residual silanol groups on the column surface resulted in the strong adsorption of liposomes and hindered their analysis. To overcome this problem, we modified the surface of the silica monolith via a two-step process and developed three silica monolithic columns coated with three different polymers: glycidyl methacrylate (GMA), 2-hydroxyethyl methacrylate (HEMA), and N-vinylpyrrolidone (VP). These were used for the analysis of 100-nm liposomal nanoparticles. Since 15% polymer coating prevented the nanoparticle adsorption, liposomes (AmBisome®) and pegylated liposomes (DOXIL®) were eluted rapidly (within 1min) using these columns, without using organic solvents in the mobile phase. Molecular leaching from the liposomes, as well as protein adsorption to the liposomes (corona formation) could be evaluated using the polymer-coated columns, thus illustrating their utility in the rapid and simple analysis of 100-nm liposomal nanoparticles.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
08:59Defining Substrate Specificities for Lipase and Phospholipase Candidates
Published on: November 23, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...