Related Experiment Video
Updated: Mar 8, 2026

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Time since discharge of 9mm cartridges by headspace analysis, part 1: Comprehensive optimisation and validation of a
M Gallidabino1, F S Romolo2, C Weyermann3
1Université de Lausanne, École des Sciences Criminelles, Bâtiment Batochime, 1015 Lausanne-Dorigny, Switzerland; King's College London, Analytical and Environmental Science Division, 150 Stamford Street, SE1 9NH London, United Kingdom.
Abstract:
Estimating the time since discharge of spent cartridges can be a valuable tool in the forensic investigation of firearm-related crimes. To reach this aim, it was previously proposed that the decrease of volatile organic compounds released during discharge is monitored over time using non-destructive headspace extraction techniques. While promising results were obtained for large-calibre cartridges (e.g., shotgun shells), handgun calibres yielded unsatisfying results. In addition to the natural complexity of the specimen itself, these can also be attributed to some selective choices in the methods development. Thus, the present series of paper aimed to more systematically evaluate the potential of headspace analysis to estimate the time since discharge of cartridges through the use of more comprehensive analytical and interpretative techniques. Specifically, in this first part, a method based on headspace sorptive extraction (HSSE) was comprehensively optimised and validated, as the latter recently proved to be a more efficient alternative than previous approaches. For this purpose, 29 volatile organic compounds were preliminary selected on the basis of previous works. A multivariate statistical approach based on design of experiments (DOE) was used to optimise variables potentially involved in interaction effects. Introduction of deuterated analogues in sampling vials was also investigated as strategy to account for analytical variations. Analysis was carried out by selected ion mode, gas chromatography coupled to mass spectrometry (GC-MS). Results showed good chromatographic resolution as well as detection limits and peak area repeatability. Application to 9mm spent cartridges confirmed that the use of co-extracted internal standards allowed for improved reproducibility of the measured signals. The validated method will be applied in the second part of this work to estimate the time since discharge of 9mm spent cartridges using multivariate models.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry