Multimodal individualized concept of hemodynamic monitoring
Zsolt Molnar1, Zsolt Szabo, Marton Nemeth
1Department of Anaesthesiology and Intensive Therapy, University of Szeged, Szeged, Hungary.
Purpose Of Review:
To discuss the pathophysiological rationale of advanced hemodynamic monitoring in the critically ill and also to highlight the importance of a multimodal, individualized approach.
Recent Findings:
There are several clinical studies and animal experiments evaluating, which hemodynamic endpoint should be the best target during fluid management. Recent systematic reviews and meta-analyses also investigated the effects of advanced hemodynamic endpoints targeted hemodynamic management on outcome mainly in high-risk surgical patients. Although most of these studies report positive results, this knowledge does not seem to affect our everyday practice. According to large international surveys, most physicians still rely on inappropriate indices. One of the reasons could be that target values applied in these studies can be misleading in the individual patient. Therefore, we describe the concept of an individualized approach, in which normalizing the components of oxygen delivery are put in the context of the patients' individual response by evaluating components of oxygen consumption, and organ perfusion.
Summary:
Advanced hemodynamic monitoring-based management provides a number of benefits, which could be better tailored for the patients' actual needs by putting this into a multimodal, individualized approach.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.