Related Experiment Video
Updated: Mar 8, 2026

Procedure to Evaluate the Efficiency of Flocculants for the Removal of Dispersed Particles from Plant Extracts
Published on: April 9, 2016
Coagulation-flocculation sequential with Fenton or Photo-Fenton processes as an alternative for the industrial
Edison GilPavas1, Izabela Dobrosz-Gómez2, Miguel Ángel Gómez-García3
1GIPAB: Grupo de Investigación en Procesos Ambientales, Departamento de Ingeniería de Procesos, Universidad EAFIT, Carrera 49 #7 sur 50, Medellín, Colombia.
Abstract:
In this study, the industrial textile wastewater was treated using a chemical-based technique (coagulation-flocculation, C-F) sequential with an advanced oxidation process (AOP: Fenton or Photo-Fenton). During the C-F, Al2(SO4)3 was used as coagulant and its optimal dose was determined using the jar test. The following operational conditions of C-F, maximizing the organic matter removal, were determined: 700 mg/L of Al2(SO4)3 at pH = 9.96. Thus, the C-F allowed to remove 98% of turbidity, 48% of Chemical Oxygen Demand (COD), and let to increase in the BOD5/COD ratio from 0.137 to 0.212. Subsequently, the C-F effluent was treated using each of AOPs. Their performances were optimized by the Response Surface Methodology (RSM) coupled with a Box-Behnken experimental design (BBD). The following optimal conditions of both Fenton (Fe2+/H2O2) and Photo-Fenton (Fe2+/H2O2/UV) processes were found: Fe2+ concentration = 1 mM, H2O2 dose = 2 mL/L (19.6 mM), and pH = 3. The combination of C-F pre-treatment with the Fenton reagent, at optimized conditions, let to remove 74% of COD during 90 min of the process. The C-F sequential with Photo-Fenton process let to reach 87% of COD removal, in the same time. Moreover, the BOD5/COD ratio increased from 0.212 to 0.68 and from 0.212 to 0.74 using Fenton and Photo-Fenton processes, respectively. Thus, the enhancement of biodegradability with the physico-chemical treatment was proved. The depletion of H2O2 was monitored during kinetic study. Strategies for improving the reaction efficiency, based on the H2O2 evolution, were also tested.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
Related Concept Videos
Coagulation
Colloidal precipitates
Precipitation and Co-precipitation
Washing, Drying, and Ignition of Precipitates
Factors Affecting Solubility