Related Experiment Video
Updated: Mar 8, 2026

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Strength of Syndesmosis Fixation: Two TightRope versus One TightRope with Plate-and-Screw Construct
Justin Tsai1, Robert Pivec1, Julio J Jauregui2
1Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY.
Abstract:
Injuries involving the distal tibiofibular syndesmosis can lead to critical destabilization of the ankle mortise. Although specific indications for operative fixation remain unclear, accurate reduction of the syndesmosis has been correlated with the best functional outcomes. The purpose of this study was to evaluate the maximum torque and rotation to failure after fixation with a novel construct. Seven pairs (14 ankles) of embalmed cadaveric lower legs, disarticulated at the knee, were obtained. Each pair was randomly assigned to receive either two TightRopes (Arthrex) or a plate-and-screw construct with one TightRope. All samples were mechanically tested in torsion to determine peak torque, torsional stiffness, and the maximum rotation angle at which failure occurred. Differences between the groups were compared using paired Student's t test. The maximum torque to failure after fixation was not significantly different between the two TightRopes (28.8 N*m; range, 7.3-49.7 N*m) and the one TightRope group (29.5 N*m; range, 9.2-44.9 N*m; p = 0.92). The maximum rotation to fracture after fixation was not significantly different between the two TightRopes (33.3 degrees; range, 21.6-57.0 degrees) and one TightRope group (38.6 degrees; range, 23.0-73.9 degrees). All specimens failed with the fracture of the fibula at the level of the inferior syndesmotic screw. The similar load to failure of the two TightRope and the one TightRope and plate-and-screw plate suggested similar stiffness between the two constructs. The addition of the plate may improve distribution of forces at the level of syndesmosis, reducing stress risers and decreasing the risk of failure, as demonstrated by a lower rotation to failure of the one TightRope with plate-and-screw construct. In addition, this construct is not likely to not be associated with any substantial cost increase. Further clinical studies may further elucidate the role of plate and/or TightRope augmentation to syndesmosis fixation.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Related Concept Videos
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Stability of structures
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Method of Joints: Problem Solving I
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
Method of Joints: Problem Solving II