Related Experiment Video
Updated: Mar 8, 2026

Non-invasive Parenchymal, Vascular and Metabolic High-frequency Ultrasound and Photoacoustic Rat Deep Brain Imaging
Published on: March 2, 2015
A non-invasive approach to investigation of ventricular blood pressure using cardiac sound features
Hong Tang1, Jinghui Zhang, Huaming Chen
1Department of Biomedical Engineering, Dalian University of Technology, Dalian 116024, People's Republic of China.
Insights
Predicting blood pressure using heart sounds (HSs) is possible. Non-spectral HS features accurately estimate left ventricular blood pressure (LVBP), offering a non-invasive monitoring alternative.
Area of Science:
- Cardiovascular Physiology
- Biomedical Signal Processing
- Artificial Intelligence in Medicine
Background:
- Heart sounds (HSs) result from complex interactions within the cardiovascular system.
- Previous studies indicate potential for predicting blood pressure from HS features, but with moderate accuracy.
- Existing methods often rely on single or combined HS features, limiting predictive power.
Purpose of the Study:
- To investigate the efficacy of various heart sound features for predicting left ventricular blood pressure (LVBP).
- To evaluate the performance of non-spectral versus spectral features in blood pressure estimation.
- To assess the potential of using heart sounds for non-invasive, real-time blood pressure monitoring.
Main Methods:
- Simultaneous recording of HSs, left ventricular blood pressure (LVBP), and electrocardiograph (ECG) signals in beagles.
- Extraction and analysis of 91 diverse features from cardiac cycles.
- Application of a neural network using distinct feature groups to predict LVBP.
Main Results:
- Non-spectral heart sound features demonstrated lower standard deviation in tracking LVBP changes.
- The non-spectral feature set achieved the highest prediction accuracy.
- High correlation (0.92) and low mean absolute error (6.86 mmHg) were observed across a wide BP range (90-282 mmHg).
Conclusions:
- Systolic blood pressure can be accurately predicted using a limited set of non-spectral heart sound features.
- This method offers a promising, non-invasive alternative for real-time blood pressure monitoring.
- Potential applications include convenient home healthcare monitoring solutions.
Abstract:
Heart sounds (HSs) are produced by the interaction of the heart valves, great vessels, and heart wall with blood flow. Previous researchers have demonstrated that blood pressure can be predicted by exploring the features of cardiac sounds. These features include the amplitude of the HSs, the ratio of the amplitude, the systolic time interval, and the spectrum of the HSs. A single feature or combinations of several features have been used for prediction of blood pressure with moderate accuracy. Experiments were conducted with three beagles under various levels of blood pressure induced by different doses of epinephrine. The HSs, blood pressure in the left ventricle and electrocardiograph signals were simultaneously recorded. A total of 31 records (18 262 cardiac beats) were collected. In this paper, 91 features in various domains are extracted and their linear correlations with the measured blood pressures are examined. These features are divided into four groups and applied individually at the input of a neural network to predict the left ventricular blood pressure (LVBP). The analysis shows that non-spectral features can track changes of the LVBP with lower standard deviation. Consequently, the non-spectral feature set gives the best prediction accuracy. The average correlation coefficient between the measured and the predicted blood pressure is 0.92 and the mean absolute error is 6.86 mmHg, even when the systolic blood pressure varies in the large range from 90 mmHg to 282 mmHg. Hence, systolic blood pressure can be accurately predicted even when using fewer HS features. This technique can be used as an alternative to real-time blood pressure monitoring and it has promising applications in home health care environments.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...