Related Experiment Video
Updated: Mar 8, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
A CAD of fully automated colonic polyp detection for contrasted and non-contrasted CT scans
Gökalp Tulum1, Bülent Bolat2, Onur Osman3
1Electrical and Electronics Engineering, Istanbul Yeni Yuzyil University Istanbul, Istanbul, Turkey. gokalp.tulum@yeniyuzyil.edu.tr.
Purpose:
Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In this paper, we aimed to develop a fully integrated CAD system for automated detection of polyps that yields a high polyp detection rate with a reasonable number of false positives.
Methods:
The proposed CAD system is a multistage implementation whose main components are: automatic colon segmentation, candidate detection, feature extraction and classification. The first element of the algorithm includes a discrete segmentation for both air and fluid regions. Colon-air regions were determined based on adaptive thresholding, and the volume/length measure was used to detect air regions. To extract the colon-fluid regions, a rule-based connectivity test was used to detect the regions belong to the colon. Potential polyp candidates were detected based on the 3D Laplacian of Gaussian filter. The geometrical features were used to reduce false-positive detections. A 2D projection image was generated to extract discriminative features as the inputs of an artificial neural network classifier.
Results:
Our CAD system performs at 100% sensitivity for polyps larger than 9 mm, 95.83% sensitivity for polyps 6-10 mm and 85.71% sensitivity for polyps smaller than 6 mm with 5.3 false positives per dataset. Also, clinically relevant polyps ([Formula: see text]6 mm) were identified with 96.67% sensitivity at 1.12 FP/dataset.
Conclusions:
To the best of our knowledge, the novel polyp candidate detection system which determines polyp candidates with LoG filters is one of the main contributions. We also propose a new 2D projection image calculation scheme to determine the distinctive features. We believe that our CAD system is highly effective for assisting radiologist interpreting CT.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:49Orthotopic Implantation of Patient-Derived Cancer Cells in Mice Recapitulates Advanced Colorectal Cancer
Published on: February 10, 2023
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT