[Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies]
P M Prodinger1, J Schauwecker2, H Mühlhofer2
1Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Straße 22, 81675, München, Deutschland. peter.prodinger@tum.de.
Abstract:
With a dislocation rate of up to 35% after revision total hip arthroplasty (THA), instability is one of the major causes why this procedure fails. Independent factors for patients at risk are age, sex, and the type of revision needed. The surgical approach, implant choice, and positioning of the components are factors that the surgeon can influence to keep the dislocation rate low. Large femoral heads or double mobility (DM) cups can increase the stability of the joint. After detailed failure analysis, targeted use of different technical innovations enhances stability in revision THA and prevents further revisions.