Related Experiment Video
Updated: Mar 8, 2026

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
Shear Wave Elastography Is a Reliable and Repeatable Method for Measuring the Elastic Modulus of the Rectus Femoris
Serkan Taş1, Mehmet Ruhi Onur2, Seval Yılmaz1
1Hacettepe University, Beytepe Hospital, Ankara, Turkey.
Objectives:
The purpose of this study was to determine intraobserver, interobserver, and inter-day reliability levels for stiffness measurements of the patellar tendon and rectus femoris muscle using shear wave elastography (SWE).
Methods:
This study was conducted on 12 healthy male individuals. Two examiners measured mean shear wave velocity values of the patellar tendons and rectus femoris muscles of both extremities using a 9L4 (4-9 MHz) transducer and an Acuson S3000 ultrasound system (Siemens Medical Solutions, Mountain View, CA). The elasticity images were acquired by the Virtual Touch tissue imaging quantification technique (Siemens Medical Solutions). Measurements were repeated 20 minutes and 1 week after the first measurements. The reliability of SWE measurements was assessed by means of the intraclass correlation coefficient (ICC).
Results:
The 12 participants ranged in age from 19 to 33 years (mean age ± SD, 25.33 ± 4.56 years). For the patellar tendon stiffness measurements with SWE, it was found that intraobserver reliability (ICC, 0.91-0.92) and interday reliability (ICC, 0.81-0.83) were excellent, and interobserver reliability (ICC, 0.71) was good. For the rectus femoris muscle stiffness measurements with SWE, it was found that the intraobserver reliability (ICC, 0.93-0.94), interday reliability (ICC, 0.81-0.91), and interobserver reliability (ICC, 0.95) were perfect.
Conclusions:
Shear wave elastography using the Virtual Touch tissue imaging quantification technique is a reliable and repeatable technique for patellar tendon and rectus femoris stiffness measurements according to intraobserver, interday, and interobserver ICC values.
Related Concept Videos
Strain and Elastic Modulus
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Elastic Strain Energy for Shearing Stresses
Elasticity in Concrete