Related Experiment Video
Updated: Mar 8, 2026

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
Case Report of False-Negative Diffusion-Weighted Image of Brain Maggnetic Resonance Imaging (MRI) in Acute Ischemic
Wei-Lun Chang1, Ji-Ching Lai2, Rong-Fu Chen2
1Department of Neurology, Chang Hua Show Chwan Memorial Hospital, Changhua, Taiwan.
Abstract:
BACKGROUND Acute ischemic stroke is a major cause of mortality and morbidity in Taiwan. Diffusion-weighted image (DWI) is a sensitive and common strategy used for imaging acute ischemic stroke. CASE REPORT We present a case of a negative DWI MRI for detecting acute ischemic stroke in a clinical setting. A 75-year-old male had a DWI performed after onset of symptoms suggesting acute ischemic stroke. The initial DWI result was negative at 72 hours of presentation. The neurological symptoms of the patient persisted and DWI was repeated. After 14 days, the DWI data confirmed and demonstrated an acute ischemic stroke. The delay in DWI confirmation, from symptom onset until DWI diagnosis, was 336 hours. CONCLUSIONS DWI may not have 100% sensitivity and accuracy in early stages of acute ischemic stroke. The time course to the development of abnormalities detected by DWI may be longer than anticipated.