A Chair-Based Unobtrusive Cuffless Blood Pressure Monitoring System Based on Pulse Arrival Time
Abstract:
In this paper, we present an unobtrusive cuffless blood pressure (BP) monitoring system based on pulse arrival time (PAT) for facilitating long-term home BP monitoring. The proposed system consists of an electrocardiograph (ECG), a photoplethysmograph (PPG), and a control circuit with a Bluetooth module, all of which are mounted on a common armchair to measure ECG and PPG signals from users while sitting on the armchair in order to calculate continuous PAT. Considering the good linear correlation of systolic BP (SBP) and the nonlinear correlation of diastolic BP (DBP) with PAT, a new BP estimation method was proposed. Ten subjects underwent BP monitoring experiments involving stationary sitting on a chair, lying on a bed, and pedaling using an ergometer in order to assess the accuracy of the estimated BP. A cuff-type BP monitor was used as reference in the experiments. Results showed that the mean difference of the estimated SBP and DBP was within 0.2 ± 5.8 mmHg ( p < 0.00001) and 0.4 ± 5.7 mmHg ( p < 0.00001), respectively, and the mean absolute difference of the estimated SBP and DBP were 4.4 and 4.6 mmHg, respectively, compared to references. Additionally, five subjects participated in data collections consisting of sitting on a chair twice a day for one month. Compared to the reference, the difference did not obviously increase along with time, even though individualized calibration was executed only once at the beginning. These results suggest that the proposed system has quite the potential for long-term home BP monitoring.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.