Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Upsampling01:22

Upsampling

676
Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
676
Bandpass Sampling01:17

Bandpass Sampling

598
In signal processing, bandpass sampling is an effective technique for sampling signals that have most of their energy concentrated within a narrow frequency band. This type of signal is known as a bandpass signal. The key principle of bandpass sampling involves sampling the signal at a rate that is greater than twice the signal's bandwidth to prevent aliasing.
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
598
Aliasing01:18

Aliasing

727
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
727
Sampling Theorem01:15

Sampling Theorem

1.5K
In signal processing, the analysis of continuous-time signals, denoted as x(t), often involves sampling techniques to convert these signals into discrete-time signals. This process is essential for digital representation and manipulation. A critical component in sampling is the train of impulses, characterized by the sampling interval and the sampling frequency. The relationship between these parameters and the original signal's properties dictates the success of the sampling process.
1.5K
Sampling Methods: Overview01:06

Sampling Methods: Overview

3.7K
A sample refers to a smaller subset representative of a larger population. In analytical chemistry, studying or analyzing an entire population is often impractical or impossible. Therefore, samples are used to draw inferences and generalize the whole population. The sampling method selects individuals or items from a population to create a sample. Standard sampling methods include random, judgemental, systematic, stratified, and cluster sampling. 
In analytical chemistry, the choice of...
3.7K
Sampling Continuous Time Signal01:11

Sampling Continuous Time Signal

806
In signal processing, a continuous-time signal can be sampled using an impulse-train sampling technique, followed by the zero-order hold method. Impulse-train sampling involves the use of a periodic impulse train, which consists of a series of delta functions spaced at regular intervals determined by the sampling period. When a continuous-time signal is multiplied by this impulse train, it generates impulses with amplitudes corresponding to the signal's values at the sampling points.
In the...
806

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Review of Algorithm & Hardware Design for AI-Based Biomedical Applications.

IEEE transactions on biomedical circuits and systems·2020
Same author

A Deep Learning Approach for Targeted Contrast-Enhanced Ultrasound Based Prostate Cancer Detection.

IEEE/ACM transactions on computational biology and bioinformatics·2018
Same author

Autophagy in long propriospinal neurons is activated after spinal cord injury in adult rats.

Neuroscience letters·2016
Same author

Prevalence of hemorrhagic fever with renal syndrome in Qingdao City, China, 2010-2014.

Scientific reports·2016
Same author

Neutralizing Antibodies to Severe Fever with Thrombocytopenia Syndrome Virus 4 Years after Hospitalization, China.

Emerging infectious diseases·2016
Same author

Elevated Platelet to Lymphocyte Ratio Is Associated with Poor Survival Outcomes in Patients with Colorectal Cancer.

PloS one·2016
Same journal

Multiplexed Crossbar GFET Array With BioADC for Multi-Modal Aptamer-Based Sensing.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A VPG-Based Adaptive Windowing PPG Sensor IC for Low-Power Wearable Monitoring.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A Chopper Amplifier with Feedforward SAR ADC Assisted DC Servo Loop Achieving ±1V DC Offset Cancellation in 2.1s for Neural Signal Recordings.

IEEE transactions on biomedical circuits and systems·2026
Same journal

ANP-R: A 22nm 0.88pJ/SOP Asynchronous SNN-based Processor with Coarse-Grained Reconfigurable Architecture Enabling Multisensory On-chip Incremental Learning for Edge AI.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A High-Efficiency Neural Processing SoC for Adaptive Closed-Loop Neuromodulation.

IEEE transactions on biomedical circuits and systems·2026
Same journal

DustNet: A Wireless Network of Ultrasonic Neural Implants.

IEEE transactions on biomedical circuits and systems·2026
See all related articles

Related Experiment Video

Updated: Mar 8, 2026

Lensless Fluorescent Microscopy on a Chip
11:23

Lensless Fluorescent Microscopy on a Chip

Published on: August 17, 2011

18.3K

Data-Driven Sampling Matrix Boolean Optimization for Energy-Efficient Biomedical Signal Acquisition by Compressive

Yuhao Wang, Xin Li, Kai Xu

    IEEE Transactions on Biomedical Circuits and Systems
    |January 24, 2017
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces an efficient method for creating optimal Boolean sampling matrices in compressive sensing. This approach significantly reduces energy consumption and hardware complexity while improving image recovery quality.

    More Related Videos

    Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
    08:58

    Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow

    Published on: October 17, 2025

    763
    Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
    11:54

    Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

    Published on: March 13, 2017

    9.9K

    Related Experiment Videos

    Last Updated: Mar 8, 2026

    Lensless Fluorescent Microscopy on a Chip
    11:23

    Lensless Fluorescent Microscopy on a Chip

    Published on: August 17, 2011

    18.3K
    Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
    08:58

    Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow

    Published on: October 17, 2025

    763
    Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
    11:54

    Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

    Published on: March 13, 2017

    9.9K

    Area of Science:

    • Biomedical Engineering
    • Signal Processing
    • Computer Science

    Background:

    • Compressive sensing (CS) is vital in biomedical applications for efficient signal acquisition.
    • The sampling matrix critically impacts signal quality and power consumption.
    • Current methods often yield real-valued matrices, leading to high energy use.

    Purpose of the Study:

    • To develop an efficient method for optimizing Boolean sampling matrices.
    • To reduce energy consumption in signal acquisition hardware.
    • To enhance image recovery quality in compressive sensing.

    Main Methods:

    • Proposing a data-driven method to find optimal Boolean sampling matrices.
    • Comparing Boolean sampling matrices against random Boolean and data-driven real-valued embeddings.
    • Evaluating improvements in image recovery quality and hardware metrics.

    Main Results:

    • The proposed data-driven Boolean sampling matrix improves image recovery quality by 9 dB compared to random Boolean embedding.
    • Energy consumption is reduced by 4.6x compared to data-driven real-valued embedding.
    • Silicon area is reduced by 1.9x compared to data-driven real-valued embedding.

    Conclusions:

    • Optimal Boolean sampling matrices offer a significant advantage in reducing energy consumption and hardware complexity for biomedical compressive sensing.
    • The proposed method achieves superior performance in both image recovery quality and hardware efficiency.
    • This work paves the way for more power-efficient and effective biomedical signal acquisition systems.