Related Experiment Video
Updated: Mar 8, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Compliance with Washington State's requirement for residential carbon monoxide alarms
Neil B Hampson1, James R Holm1
1Center for Hyperbaric Medicine, Department of Medicine, Virginia Mason Medical Center, Seattle, WA, United States.
Abstract:
Carbon monoxide (CO) poisoning is responsible for significant morbidity and mortality in the US. In response, a majority of states have passed legislation in recent years requiring the installation of residential CO alarms. There is, however, no published information evaluating compliance with such laws. Employees of a Seattle medical center were surveyed in 2008 regarding home use of CO and smoke alarms. Washington State enacted legislation requiring residential CO alarms by all residences by January 1, 2013. The survey was repeated in mid-2016 to evaluate compliance. In 2016, a total of 354 employees completed the survey and their responses were compared to an equal number of 2008 survey respondents matched by home ownership and ZIP code. Residential CO alarm use rose from 37% to 78% (p < 0.0001). Among homeowners, 78% had alarms while 80% of renters had them. Homeowners with the highest compliance (96%) had purchased their homes since January 1, 2013 while those with the lowest compliance (73%) had purchased them earlier. A majority (79%) of renters without alarms reported the reason was that their landlord did not provide one, a violation of the law. Only one-half to two-thirds of all equipped homes had the required number of either CO or smoke alarms. Use of residential CO alarms increased significantly in this study population three years after law required them. Areas for further improvement include education of landlords, tenants, and longtime homeowners about the law, as well as public education regarding the number of CO and smoke alarms needed.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Household Wiring And Electrical Safety
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.