Two interpolating filters for scatter estimation.

F C Wagner1, A Macovski, D G Nishimura

  • 1Information Systems Laboratory, Stanford University, California 94305-4055.

Medical Physics
|September 1, 1989
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

BMI is independently associated with ARDS, sepsis and multiorgan failure after major trauma-results of a high-volume retrospective observational cohort study.

Scandinavian journal of trauma, resuscitation and emergency medicine·2026
Same author

Biological sex, but not obesity, independently predicts anatomical injury patterns in trauma bay patients: a multivariate retrospective analysis of 2,128 patients.

Biology of sex differences·2026
Same author

Obesity significantly elevates thromboembolism risk in severe trauma, yet essential resuscitation with TXA and erythrocytes remains safe.

European journal of trauma and emergency surgery : official publication of the European Trauma Society·2026
Same author

Biomechanical evaluation of two innovative locking implants for comminuted olecranon fractures under high-cycle loading conditions.

Injury·2015
Same author

Clinical evaluation of reduced field-of-view diffusion-weighted imaging of the cervical and thoracic spine and spinal cord.

AJNR. American journal of neuroradiology·2012
Same author

The microvasculature in transitory traumatic paraplegia. An electron microscopic study in the monkey.

Journal of neurosurgery·2011
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

This study introduces a new scatter-correction method using interpolating filters like sinc and jinc functions for improved medical imaging. While it reduces artifacts, further refinement is needed for optimal performance in vessel and energy-subtraction imaging.

Area of Science:

  • Medical Imaging
  • Image Processing
  • Radiological Physics

Background:

  • Scatter radiation degrades image quality in medical imaging.
  • Previous dual-measurement techniques employed least-squares interpolation for scatter estimation.
  • Classical sampling theory provides a basis for improved scatter estimation methods.

Purpose of the Study:

  • To present a novel scatter-correction technique utilizing interpolating filters based on sampling theory.
  • To evaluate the performance of sinc and jinc filters for scatter estimation in medical imaging.
  • To address and mitigate aliasing artifacts observed in scatter-corrected images.

Main Methods:

  • A sample-and-estimate technique was employed, collecting scatter samples using lead disks during the first measurement.

Related Experiment Videos

  • Scatter estimation was performed by convolving the sample set with sinc and jinc interpolating filters.
  • The estimated scatter was subtracted from a second measurement to obtain a scatter-corrected image.
  • Main Results:

    • Application of sinc and jinc filters in phantom studies for vessel and energy-subtraction imaging demonstrated improved image quality.
    • Initial scatter-corrected images exhibited aliasing artifacts, which were subsequently reduced by modifying filter widths.
    • Despite improvements, the aliasing artifact persisted, indicating a need for further optimization.

    Conclusions:

    • Interpolating filters derived from sampling theory offer a promising approach for scatter correction in medical imaging.
    • The use of sinc and jinc functions, while beneficial, requires further development to fully eliminate aliasing artifacts.
    • Future research should focus on refining filter parameters and exploring alternative methods to enhance scatter-correction performance.