Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Mar 8, 2026

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency
07:22

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency

Published on: January 15, 2017

9.3K

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency.

Dong Wang1, Grigol Tediashvili2, Simon Pecha3

  • 1Transplant and Stem Cell Immunobiology Lab, University Heart Center Hamburg; Department of Surgery, Transplant and Stem Cell Immunobiology Lab, University of California San Francisco (UCSF); Cardiovascular Research Center (CVRC) and DZHK German Center for Cardiovascular Research), partner site Hamburg/Kiel/Luebeck; Cardiovascular Surgery, University Heart Center Hamburg.

Journal of Visualized Experiments : Jove
|January 25, 2017
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pyrolytic hydrocarbon growth from cyclopentadiene.

The journal of physical chemistry. A·2010
Same author

In(III)-catalyzed tandem reaction of chromone-derived Morita-Baylis-Hillman alcohols with amines.

Organic & biomolecular chemistry·2010
Same author

Regression-based multi-trait QTL mapping using a structural equation model.

Statistical applications in genetics and molecular biology·2010
Same author

Elevated expression of APE1/Ref-1 and its regulation on IL-6 and IL-8 in bone marrow stromal cells of multiple myeloma.

Clinical lymphoma, myeloma & leukemia·2010
Same author

Accelerated aging of intervertebral discs in a mouse model of progeria.

Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2010
Same author

The synthesis of a multiblock osteotropic polyrotaxane by copper(I)-catalyzed huisgen 1,3-dipolar cycloaddition.

Macromolecular bioscience·2010
Same journal

A Video Protocol of a Randomized Controlled Clinical Trial - Electrochemotherapy of Cutaneous Metastases with Reduced Dose Bleomycin (BLESS Trial).

Journal of visualized experiments : JoVE·2026
Same journal

A Standardized Ex Vivo Porcine Oromucosal Model for Evaluating Peptide Fluxes.

Journal of visualized experiments : JoVE·2026
Same journal

Lightweight English Text Classification with Deep Learning Based on Complex System Theory.

Journal of visualized experiments : JoVE·2026
Same journal

Integrating Artificial Intelligence-Assisted Translation Support into English Courses: Effects on Translation Accuracy, Perceived Stress, and Anxiety.

Journal of visualized experiments : JoVE·2026
Same journal

A Toxin-Based Counter-Selection System for Markerless Gene Deletion and High-Density Tn5 Transposon Mutagenesis in Pectobacterium brasiliense.

Journal of visualized experiments : JoVE·2026
Same journal

Seamless Multimodal Human-Robot Communication: Integration Techniques in Human-Computer Interaction.

Journal of visualized experiments : JoVE·2026
See all related articles
This summary is machine-generated.

This study introduces a rat model for studying vein graft failure, a common issue in bypass grafting. This accessible model helps researchers understand how grafts lose patency, focusing on myointimal hyperplasia.

Area of Science:

  • Cardiovascular Surgery
  • Surgical Research
  • Animal Models

Background:

  • Coronary artery disease is frequently treated with bypass grafting.
  • Saphenous vein graft failure remains a significant clinical challenge.
  • Understanding graft failure mechanisms requires effective research models.

Purpose of the Study:

  • To describe a rat vein interposition model for investigating vein graft patency loss.
  • To provide an accessible and cost-effective alternative to large animal models.
  • To facilitate research into the pathobiology of graft failure.

Main Methods:

  • Harvesting the rat inferior epigastric vein for femoral artery interposition.
  • Performing anastomosis using single stitches and fibrin glue.

More Related Videos

A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure
07:02

A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure

Published on: May 15, 2020

6.4K
Establishment and Evaluation of a Porcine Vein Graft Disease Model
08:50

Establishment and Evaluation of a Porcine Vein Graft Disease Model

Published on: July 25, 2022

2.3K

Related Experiment Videos

Last Updated: Mar 8, 2026

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency
07:22

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency

Published on: January 15, 2017

9.3K
A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure
07:02

A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure

Published on: May 15, 2020

6.4K
Establishment and Evaluation of a Porcine Vein Graft Disease Model
08:50

Establishment and Evaluation of a Porcine Vein Graft Disease Model

Published on: July 25, 2022

2.3K
  • Non-invasive monitoring of graft patency via duplex sonography.
  • Histological analysis to assess myointimal hyperplasia.
  • Main Results:

    • The rat model allows for the study of progressive myointimal hyperplasia, a key factor in graft failure.
    • The model provides sufficient biological material for diverse analyses.
    • Graft patency can be reliably monitored throughout the study period.

    Conclusions:

    • The rat vein interposition model is a valuable tool for studying vein graft patency loss.
    • This model offers advantages in terms of cost, handling, and operability compared to larger animals.
    • Further research using this model can elucidate mechanisms of bypass graft failure.