Organ Doses to Airline Passengers Screened by X-Ray Backscatter Imaging Systems
Elliott J Stepusin1, Matthew R Maynard1, Shannon E O'Reilly1
1a J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611-6131 and.
Abstract:
Advanced imaging technologies (AIT) are being developed for passenger airline transportation. They are designed to provide enhanced security benefits by identifying objects on passengers that would not be detected by methodologies now used for routine surveillance. X-ray backscatter imaging is one AIT system being considered. Since this technology is based on scanning passengers with ionizing radiation, concern has been raised relating to the health risks associated with these exposures. Recommendations for standards of radiation safety have been proposed by the American National Standards Institute published in ANSI/HPS N43.17-2009. A Monte Carlo based methodology for estimating organ doses received from an X-ray backscatter AIT system is presented. Radiological properties of a reference scanner including beam intensity, geometry and energy spectra were modeled based on previous studies and physical measurements. These parameters were incorporated into a Monte Carlo source subroutine and validated with comparison of simulated versus measured data. One extension of this study was to calculate organ and effective dose on a wide range of potential passengers. Computational phantoms with realistic morphologies were used including adults of 5th, 25th, 50th, 75th and 95th percentile weight, children of 5th, 50th and 95th percentile weight, and the developing fetus of 15, 25, and 38 weeks after conception. Additional sensitivity studies were performed to evaluate effects of passenger positioning within the scanner, energy spectrum and beam geometry, as well as failure mode analyses. Results for routine operations yielded a maximum effective dose to the adult and pediatric passengers of 15 and 25 nSv per screen, respectively. The developing fetus received a maximum organ dose and whole body dose of 16 nGy and 8.5 nGy per screen, respectively. The sensitivity analyses indicated that variations in positioning, energy spectra, and beam geometry yielded a range of effective doses per screen that were an order of magnitude below the ANSI recommendation.
More Related Videos
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
09:08Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
The Electromagnetic Spectrum
Imaging Studies for Cardiovascular System V: CT