Risk factors associated with failure of extubation in very-low-birth-weight newborns
Slobodan Spasojevic1,2, Aleksandra Doronjski1,2
1a Department of Intensive Care , Institute of Child and Youth Healthcare of Vojvodina , Novi Sad , Serbia.
Aim:
To identify risk factors associated with the failure of extubation of mechanically ventilated very-low-birth-weight newborns.
Study Design:
Prospective observational study. Assessment of the occurrence of extubation failure in relation to demographic and ventilation parameters, the SpO2/FiO2 ratio, the spontaneous breathing test (SBT) and values of the Silverman-Andersen score (SAS). Extubation failure was defined as the need for reintubation for any reason within 72 h after extubation.
Results:
Extubation failed in 14/50 (28%) patients. Tidal volume applied at the moment of extubation (p = 0.030), the values of the SpO2/FiO2 ratio (p = 0.006), SBT (p = 0.034) and SAS measured for 60 min after extubation and later (p = 0.010, p = 0.000001, p∼0.000, respectively) showed a significant association with reintubation.
Conclusions:
Measured TV, SpO2/FiO2 ratio, SBT at the moment of extubation and values of SAS starting 1 h after extubation might be valuable parameters in identifying those VLBW newborns in the risk to fail extubation.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-III
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...