Construction and application of a new cell electrochemical detecting system based on the hyposmotic principle
Ji-Wen Cui1, Qian Wang, Sheng Bi
1College of Pharmacy, Jiamusi University, Jiamusi, 154000, China. dmwu@jmsu.edu.cn.
The Analyst
|January 26, 2017
Abstract:
A new cell electrochemical detecting system has been constructed based on the hyposmotic principle, in which the electrochemical signals have been strengthened by about 109.75% for the signal at about +0.70 V and 532.94% for the signal at about +1.03 V. The electrochemical detection limits of the cells have been improved by one order of magnitude. The individual concentrations of intracellular purines have been obtained.
Related Concept Videos
Potentiometry: Membrane Electrodes
2.0K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.0K
Concentration Cells
26.3K
A concentration cell is a type of a voltaic cell constructed by connecting two almost identical half-cells, both based on the same half-reaction and using the same electrode, differing only in the concentration of one redox species. A concentration cell's potential, therefore, is determined only by the concentration difference of the particular redox species.
Consider the following voltaic cell:
Consider the following voltaic cell:
26.3K
Concentration Cells
88
A concentration cell is an electrochemical cell in which the emf arises from a difference in concentration of a species between two half-cells. Unlike galvanic cells, where electrical energy comes from a chemical reaction, the driving force here is the transfer of matter from a region of higher concentration to lower concentration. The overall process is therefore physical in nature. A classic illustration is a cell made of two chlorine electrodes operating at different chlorine gas...
88
Controlled-Potential Coulometry: Electrolytic Methods
802
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
802
Amperometry: Overview
2.0K
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
2.0K
Electrochemical Cells
36
Electrochemical cells are systems that convert chemical energy into electrical energy or use electrical energy to drive chemical reactions. They consist of two electrodes in contact with an electrolyte, where redox reactions enable electron transfer. Most electrochemical cells include two half-cells connected by an external wire for electron flow and a salt bridge for ion flow. The salt bridge contains an electrolyte solution and maintains charge neutrality by allowing ions—not...
36